<?xml version="1.0"?>
<Articles JournalTitle="International Journal of Occupational Hygiene">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>International Journal of Occupational Hygiene</JournalTitle>
      <Issn>2008-5109</Issn>
      <Volume>5</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="epublish">
        <Year>2015</Year>
        <Month>10</Month>
        <Day>11</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Application of Solid Phase Microextraction followed by Chromatograph-Flame Ionization Detector for Sampling and Analysis of Acetonitrile in Air</title>
    <FirstPage>177</FirstPage>
    <LastPage>183</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>NEMATULLAH</FirstName>
        <LastName>KURD</LastName>
        <affiliation locale="en_US">Department of Occupational Health Engineering, Hamedan University of Medical Sciences, Hamadan, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>ABDULRAHMAN</FirstName>
        <LastName>BAHRAMI</LastName>
        <affiliation locale="en_US">Research Centre for Health Sciences, Faculty of Health, Hamedan University of Medical Sciences, Hamadan, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>FARSHID</FirstName>
        <LastName>GHORBANI-SHAHNA</LastName>
        <affiliation locale="en_US">Research Centre for Health Sciences, Faculty of Health, Hamedan University of Medical Sciences, Hamadan, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>MAHMOUD</FirstName>
        <LastName>HEIDARI</LastName>
        <affiliation locale="en_US">Department of Occupational Health, Faculty of Health, Guilan University of Medical Sciences, Rasht, Iran.</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2015</Year>
        <Month>10</Month>
        <Day>11</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2015</Year>
        <Month>10</Month>
        <Day>11</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Acetonitrile used as a solvent in manufactures and affects to central nervous system from inhalation exposure. The aim of this study was to develop a micro-solid phase extraction method for&#xA0; the determination of acetonitrile in the air matrix. The sampling was performed with a small diameter fused silica fiber coated with a thin film of stationary phase and was subsequently desorbed and analyzed by gas chromatograph equipped with a flame ionization detector (GC/FID). The effects of laboratory and sampling parameters were investigated and applied to the determination of acetonitrile in air matrix. The Carboxen/PDMS&#xA0; as the coating fiber showed better analytical performances compared to the PDMS fiber. Analysis of the data by ANOVA test at a 0.05 level of accuracy showed that the peak area of the sampler was significantly affected by temperature and humidity so that the optimum temperature was 20&#xB0;C and the optimum humidity was 35%. Besides, the limit of detection (LOD) and limit of quantification (LOQ) for acetonitrile in the GC system were 0.05 and 0.15 &#x3BC;g/ml, respectively. The solid phase&#xA0; microextraction (SPME) has been shown a suitable technique for sampling and analysis of acetonitrile in air. There was a good correlation between the SPME and national institute occupational safety and health (NIOSH) 1010 method under the optimum conditions.</abstract>
    <web_url>https://ijoh.tums.ac.ir/index.php/ijoh/article/view/86</web_url>
    <pdf_url>https://ijoh.tums.ac.ir/index.php/ijoh/article/download/86/86</pdf_url>
  </Article>
</Articles>
rticle>
</Articles>
