The Respirator Fitting Characteristics: The Emerging but Negligent Issues Influencing Optimal Respiratory Protection against New Coronavirus (Covid-19)

Abstract

Abstract

According to the hierarchy of hazard controls, respiratory protective ‎equipment (RPE) is considered as the last prevention and control measure ‎against chemical and biological respiratory hazards. However, the correct ‎application of‎ these kinds of personal protective equipment (PPE) as the only ‎control means are inevitably unavoidable during aerosol-generating procedures ‎‎ (AGPs) such as tracheal intubation, noninvasive ventilation, and ‎tracheostomy and so on‎. Nonetheless, two vital factors influencing the optimal use of RPE are as ‎follows: the filtration efficiency of the respirator and the fitting characteristics ‎of the respirator into the subjects’ facial dimensions to ensure the appropriate ‎respiratory protection. It is of utmost importance for HCP, while they are conducting high-risk ‎procedures during emergencies such as the outbreak of the Covid-19‎.

 

1. OSHA. Occupational Safety and Health Administration Title 29 CFR.1910.134 App A. Respiratory protection program Standards- Fit Testing Procedures (Mandatory). 2016.
2. CDC. Centers for Disease Control and Prevention, Hierarchy of Controls 2015.
3. Mueller W, Horwell CJ, Apsley A, et al. The effectiveness of respiratory protection worn by communities to protect from volcanic ash inhalation. Part I: Filtration efficiency tests. Int J Hyg Environ Health. 2018; 221: 967-76.
4. NIOSH. The National Institute for Occupational Safety and Health. NIOSH Guide to the Selection and Use of Particulate Respirators. 1996.
5. EN149. Respiratory protective devices — Filtering half masks to protect against particles —Requirements, testing, marking. 2009.
6. Racz L, Yamamoto DP, Eninger RM. Handbook of Respiratory Protection: Safeguarding Against Current and Emerging Hazards. CRC Press, 2017.
7. ANSI-Z88.10. American National Standards Institute - Respirator Fit testing Methods (ANSI/AIHA Z88.10–2010). 2010: 40.
8. ISO-16975-3. International Organization for Standardization (ISO), ISO 16975-3, Respiratory protective devices-Selection, use and maintenance- Part 3: Fit Testing procedures. [Standard]. 2017.
9. EN529. British Standard- Respiratory protective devices – Recommendations for selection, use, care and maintenance – Guidance document 2005.
10. Mitchell BG, Wells A, McGregor A, et al. Can homemade fit testing solutions be as effective as commercial products? Healthcare infection. 2012; 17: 111-14.
11. Mullins HE, Danisch SG, Johnston AR. Development of a new qualitative test for fit testing respirators. American Industrial Hygiene Association journal. 1995; 56: 1068-73.
12. TSI. Quantitative vs. Qualitative Fit Testing: Simulated N95 Protection Factors by Testing Method. 2019.
13. Colton CE. Respirator fit testing: choosing the best method. Metal Finishing. 2001; 99: 53-55.
14. Campbell D, Coffey C, Lenhart S. Respiratory protection as a function of respirator fitting characteristics and fit-test accuracy. AIHAJ-American Industrial Hygiene Association. 2001; 62: 36-44.
Files
IssueVol 12 No 2 (2020) QRcode
SectionEditorial
Published2020-07-30
Keywords
Respiratory Protection Fit Testing Procedure Filter Efficiency Pandemics New Corona Virus (Covid-19)

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Fakherpour A, Jahangiri M. The Respirator Fitting Characteristics: The Emerging but Negligent Issues Influencing Optimal Respiratory Protection against New Coronavirus (Covid-19). Int J Occup Hyg. 2020;12(2):176-179.